Xinxiang Jiahe Make Cold Co.LTD
|
|
| |
|
|
|
|

|

|
Click to enlarge image
|
|
|
The free CFC Cleanliness Standard: residual moisture ≤20mg/, residual impurity ≤30mg/, residual mineral oil≤7mg/, chloride content ≤0.3mg/, wax content ≤0.2mg/.
Coating Quality Standard1、Coating Thickness: zinc coating + varnish paint, 12-30μm; electrophoresis dip painting, 12-25μm, electrophoresis + powder injection, 60-180μm. 2、Coating Impact Resistance: 50kg/cm, without cracking and abscission.
3、Coating Hardness: ≥2H 4、Adhesion: LevelⅠ(cross cut test
5、Brightness: ≥86% 6、Flexibility: 3D core axle, without cracking and abscission. 7、Corrosion Resistance: accord to HG/T2006-91, GB/T1771-91, injection painting of 400h, without corrosion, GB2423 galvanizing.
|
|
Technical Properties
|
| Main Material |
1.Evaporator tube: coiling welded pipe 8×0.71 2.Steel wire: low carbon steel wire 1.4~1.6 3.Bracket: cold rolled plate t=0.6~0.9
|
| Structure Type |
Evaporator for Single Temperature Control System (Single Capillary Evaporator)
Evaporator for Double Temperature Control System (Double Capillary Evaporator)
Evaporator for Triple Temperature Control System (Triple Capillary Evaporator)
|
| Main Process |
Bending, thread tube welding, single piece assembling, unit welding, leakage test, cleaning, surface painting, inspection and package.
|
| Technical Capacity |
Steel wire distance ≥5mm. We can produce according to drawing or sample provided by client, also can help them design and produce different type of thread tube evaporators used for different size of refrigerators.
|
| Product Properties |
1.The product can meet anti-corrosion requirement through electrophoresis or powder injection.
2.The internal cleanliness can meet R134a or CFC refrigeration system requirements. 3.It can meet freezing requirement of all refrigerators design
|
|
|
|
|
|
| |
|
|
|